Agnus/
Read/ Denise/
Register Address Write Paula Function
-------- ------- ----- ------- --------
COPCON 02E W A( e ) copper control register
This is a 1-bit register that when set true, allows
the Copper to access the blitter hardware. This
bit is cleared by power-on reset, so that the Copper
cannot access the blitter hardware. See Appendix C
for ECS operation.
BIT# NAME FUNCTION
---- ------- ------------------
01 CDANG Copper danger mode. Allows Copper
access to blitter if true.