Agnus/
Read/ Denise/
Register Address Write Paula Function
-------- ------- ----- ------- --------
BLTAFWM 044 W A Blitter first-word mask for source A
BLTALWM 046 W A Blitter last-word mask for source A
The patterns in these two registers are ANDed with
the first and last words of each line of data from
source A into the blitter. A zero in any bit
overrides data from source A. These registers
should be set to all 1s for fill mode or for
line-drawing mode.