Agnus/ Read/ Denise/ Register Address Write Paula Function -------- ------- ----- ------- -------- ADKCON 09E W P Audio, disk, control write ADKCONR 010 R P Audio, disk, control read BIT# USE ---- ------------------------------------ 15 SET/CLR Set/clear control bit. Determines if bits written with a 1 get set or cleared. Bits written with a zero are always unchanged. 14-13 PRECOMP 1-0 CODE PRECOMP VALUE ---- ------------- 00 none 01 140 ns 10 280 ns 11 560 ns 12 MFMPREC ( 1=MFM precomp 0=GCR precomp) 11 UARTBRK Forces a UART break (clears TXD) if true. 10 WORDSYNC Enables disk read synchronizing on a word equal to DISK SYNC CODE, located in address (3F)*2. 09 MSBSYNC Enables disk read synchronizing on the MSB (most significant bit). Appl type GCR. 08 FAST Disk data clock rate control 1=fast(2us) 0=slow(4us). (fast for MFM, slow for MFM or GCR) 07 USE3PN Use audio channel 3 to modulate nothing. 06 USE2P3 Use audio channel 2 to modulate period of channel 3. 05 USE1P2 Use audio channel 1 to modulate period of channel 2. 04 USE0P1 Use audio channel 0 to modulate period of channel 1. 03 USE3VN Use audio channel 3 to modulate nothing. 02 USE2V3 Use audio channel 2 to modulate volume of channel 3. 01 USE1V2 Use audio channel 1 to modulate volume of channel 2. 00 USE0V1 Use audio channel 0 to modulate volume of channel 1. NOTE: If both period and volume are modulated on the same channel, the period and volume will be alternated. First word xxxxxxxx V6-V0 , Second word P15-P0 (etc)